IJRET
  • CrossRef
  • Google Scholar
  • ischolar
  • Index Copernicus
  • IJRET
  • Alternate Text
  • IJRET
  • IJRET
  • IJRET
  • Alternate Text
  • IJRET
  • IJRET
  • IJRET
  • IJRET
  • IJRET
  • IJRET
  • IJRET
Authors will receive one hard copy of full paper, individual print certificates and digital certificates, Submit Manuscript

CALL FOR PAPERS : DEC-2018

Submission Last Date :  30-Dec-2018
Acceptance Notification :  in 15 days
Publication Date :  in 5 days
Submit Manuscript Online

FOR AUTHORS

FOR REVIEWERS

IJRET® PUBLICATIONS

DOWNLOADS

CONTACT US

NEWS & UPDATES

Call for Paper Vol-7 Iss-02 Feb-2018

IJRET invites papers from various engineering disciplines for Volume-07 Issue-02, Feb-2018.

Submit Manuscript

Published Vol-07 Iss-01 Jan-18

IJRET Volume-07 Issue-01, Jan-2018 is published now.

Browse Papers

EXPERIMENTAL INVESTIGATION ON TRIPLE BLENDED SCC FILLED STEEL TUBES WITH AND WITHOUT STIFFENERS

Naveen Kumar Y R, Sharada S A, G Narayana

Abstract: Concrete filled steel tubular columns are gaining its popularity in engineering practice. However, local buckling is the main criteria which effects on strength and ductility for the composite columns. In order to enhance their overall performance, one of the most effective measures is to provide stiffeners for the steel tubes. In the present research, experimental studies have been devoted to investigating the behavior of self-compacting Concrete Filled Steel Tube (CFST) stub columns strengthened by single or double stiffeners. A total of 36 stub columns specimen under monotonic compression load were tested in order to discover the best configuration of column system where (specimen having zero stiffeners, single stiffener, double stiffeners) each for hollow steel and with SCC in-filled are tested for 7 days, 28 days and 56 days strength with circular cross-sections of dimensions 300mm height x100mm diameter x 2mm thickness. The experimental results indicated that the use of Stiffeners strengthen the CFST has a significant effect on the overall behavior of CFST such as enhancement on its strength and ductility. Also the Stiffeners confinement delays local buckling of steel tube, prevents a sudden strength reduction caused by the local buckling of the steel tube, and increases lateral confinement of the concrete core. It is found that the best configuration of Stiffeners in the Steel tubes is providing it in transverse direction with single and double stiffeners at a height of h/2 and h/3 respectively.

Keywords: Composite Columns, Concrete Filled Steel Tube, Stiffeners, Self Compact Concrete etc.,

DOI: https://doi.org/10.15623/ijret.2016.0508012

Home | Publication Ethics | Privacy Policy | Terms & Conditions | Refund Policy | Feedback | Contact Us
Copyright © 2012-2018 IJRET Journal All rights reserved