IJRET
  • CrossRef
  • Google Scholar
  • ischolar
  • Index Copernicus
  • IJRET
  • Alternate Text
  • IJRET
  • IJRET
  • IJRET
  • Alternate Text
  • IJRET
  • IJRET
  • IJRET
  • IJRET
  • IJRET
  • IJRET
  • IJRET
Authors will receive one hard copy of full paper, individual print certificates and digital certificates, Submit Manuscript

CALL FOR PAPERS : DEC-2018

Submission Last Date :  30-Dec-2018
Acceptance Notification :  in 15 days
Publication Date :  in 5 days
Submit Manuscript Online

FOR AUTHORS

FOR REVIEWERS

IJRET® PUBLICATIONS

DOWNLOADS

CONTACT US

NEWS & UPDATES

Call for Paper Vol-7 Iss-02 Feb-2018

IJRET invites papers from various engineering disciplines for Volume-07 Issue-02, Feb-2018.

Submit Manuscript

Published Vol-07 Iss-01 Jan-18

IJRET Volume-07 Issue-01, Jan-2018 is published now.

Browse Papers

A NOVEL HIGH EFFICIENCY CONVERTER FOR RENEWABLE ENERGY GENERATION APPLICATIONS

Chaitanya.M.K., A.Kumar

Abstract: Resonant converters are those, which has the L and C components that would provide a sinusoidal voltage or current wave during any sub interval in the switching interval. These wave form help in obtaining the Zero Voltage and Zero Current Switching to occur in the converters. The topology of the resonant converters uses the different combination of inductor and capacitors to obtain this property. The combination of this inductor and the capacitor is called the resonant tank. This project is to develop such a resonant converter, which utilizes the LLC resonant tank. This is a full bridge topology, which is a isolated topology in DC-DC converter topology. The isolation is happening because of the high frequency transformer placed between the inverter in the sourceside and the converter in the load side. The high frequency is obtained by switches of inverter in HF mode to supply to the source of the HF transformer. The multiphase converters are the main source that is used in the high performance point of load converters. This project uses the two-phase converter, which would split the current path into two in the source side. As the two currents join in the output capacitor the ripple at the output is reduced to half the value as the frequency of the ripple is doubled.The simulation work was carried out for both high efficiency LLC converter and full bridge converter of 14V input. Here, the efficiency of both the converters are calculated and was proved that efficiency of proposed system is higher than that of resonant converter of full bridge

Keywords: High Efficiency Converter, Resonant Converter For Full Bridge, Efficiency, Output Current Ripple and PWM Control

DOI: https://doi.org/10.15623/ijret.2016.0505053

Home | Publication Ethics | Privacy Policy | Terms & Conditions | Refund Policy | Feedback | Contact Us
Copyright © 2012-2018 IJRET Journal All rights reserved