IJRET
  • CrossRef
  • Google Scholar
  • ischolar
  • Index Copernicus
  • IJRET
  • Alternate Text
  • IJRET
  • IJRET
  • IJRET
  • Alternate Text
  • IJRET
  • IJRET
  • IJRET
  • IJRET
  • IJRET
  • IJRET
  • IJRET
Authors will receive one hard copy of full paper, individual print certificates and digital certificates, Submit Manuscript

CALL FOR PAPERS : DEC-2018

Submission Last Date :  30-Dec-2018
Acceptance Notification :  in 15 days
Publication Date :  in 5 days
Submit Manuscript Online

FOR AUTHORS

FOR REVIEWERS

IJRET® PUBLICATIONS

DOWNLOADS

CONTACT US

NEWS & UPDATES

Call for Paper Vol-7 Iss-02 Feb-2018

IJRET invites papers from various engineering disciplines for Volume-07 Issue-02, Feb-2018.

Submit Manuscript

Published Vol-07 Iss-01 Jan-18

IJRET Volume-07 Issue-01, Jan-2018 is published now.

Browse Papers

COMPARATIVE STUDY OF SEIMIC ANALYSIS OF A NORMAL BUILDING AND BUILDING WITH FLOATING COLUMNS

D. Annapurna, Sriram Nadipelli

Abstract: In urban India buildings with floating column is a typical feature in the modern multistory construction. Floating columns are generally adopted to create more space in the ground floor. Such features are highly undesirable in building built in seismically active areas. The Indian Standard code IS-1893: 2002 (Part-I) defines a number of structural irregularities. Floating column is one of the structural irregularity in buildings. This project studies the analysis of G+5 story normal building and a G+5 story floating column building for external lateral forces. The analysis is done by the use of E-Tabs software by using equivalent static analysis. It also studies the variation of the both structures by applying the intensities of the past earthquakes i.e., applying the ground motions to the both structures, from that displacement time history values are compared .The present paper deals with the variation of time period, displacement of structure, base shear, seismic weight of building from manual calculations and E-Tabs. For a general column building and floating column building, finding the variations between them and describes what happens when variation may be high or low. This study is to find whether the structure is safe or unsafe with floating column when built in seismically active areas and also to find floating column building is economical or uneconomical

Keywords: Floating column building, Normal building, E-tabs.

DOI: https://doi.org/10.15623/ijret.2015.0425006

Home | Publication Ethics | Privacy Policy | Terms & Conditions | Refund Policy | Feedback | Contact Us
Copyright © 2012-2018 IJRET Journal All rights reserved