IJRET
  • CrossRef
  • Google Scholar
  • ischolar
  • Index Copernicus
  • IJRET
  • Alternate Text
  • IJRET
  • IJRET
  • IJRET
  • Alternate Text
  • IJRET
  • IJRET
  • IJRET
  • IJRET
  • IJRET
  • IJRET
  • IJRET
Authors will receive one hard copy of full paper, individual print certificates and digital certificates, Submit Manuscript

CALL FOR PAPERS : DEC-2018

Submission Last Date :  30-Dec-2018
Acceptance Notification :  in 15 days
Publication Date :  in 5 days
Submit Manuscript Online

FOR AUTHORS

FOR REVIEWERS

IJRET® PUBLICATIONS

DOWNLOADS

CONTACT US

NEWS & UPDATES

Call for Paper Vol-7 Iss-02 Feb-2018

IJRET invites papers from various engineering disciplines for Volume-07 Issue-02, Feb-2018.

Submit Manuscript

Published Vol-07 Iss-01 Jan-18

IJRET Volume-07 Issue-01, Jan-2018 is published now.

Browse Papers

UTILIZATION OF PRE-AERATED SLUDGE IN ACTIVATED SLUDGE PROCESS

Sagar Gawande, Archana V. Kelkar

Abstract: The research was carried out with Pre aerated Sludge in Activated Sludge Process to observe the effect of Pre-aerated Sludge on BOD, COD , Phosphate, Nitrate, MLVSS mainly in treatment of dairy wastewater. The experimental process involves the conventional Activated Sludge Process (ASP) in which microorganisms are kept in suspension by mixing and aerating the wastewater. The study is to be conducted by following two methods: 1) utilizing non pre-aerated sludge and 2) utilizing preaerated sludge. In the first method the dairy wastewater measuring five liters and 400 ml of non-pre-aerated sludge is filled in the aeration tank and was aerated in the aeration tank where air (or oxygen) was supplied for regular intervals of 30, 60, 90, 120 minutes respectively and samples are collected before aeration and at regular intervals. In the second method the dairy wastewater measuring five liters and 400 ml of pre aerated sludge (with 20, 40 and 60 minutes pre-aeration) are filled in aeration tank. This tank is aerated for regular intervals of 30, 60, 90, 120 minutes respectively. The samples are collected before aeration and at regular time intervals. The sludge is to be not recycled to the aeration tank. Testing of different parameters like BOD, COD, Phosphate, Nitrate and Mixed liquor volatile suspended solids was carried out on the samples aerated with different aeration time, with and without pre-aerated sludge and consequent results are to be found. By utilization of pre-aerated sludge, the concentrations of various parameters to be considered for study are to be found decreased when compared with the values of concentration without using pre-aerated sludge. It will be very clear that removal of various parameters from wastewater is effective up to the optimum period for pre-aeration beyond this period removal of various parameters from wastewater will not be effective.

Keywords: Activated Sludge Process, BOD, COD, Phosphate, Nitrate, MLVSS.

DOI: https://doi.org/10.15623/ijret.2015.0405054

Home | Publication Ethics | Privacy Policy | Terms & Conditions | Refund Policy | Feedback | Contact Us
Copyright © 2012-2018 IJRET Journal All rights reserved