IJRET
  • CrossRef
  • Google Scholar
  • ischolar
  • Index Copernicus
  • IJRET
  • Alternate Text
  • IJRET
  • IJRET
  • IJRET
  • Alternate Text
  • IJRET
  • IJRET
  • IJRET
  • IJRET
  • IJRET
  • IJRET
  • IJRET
Authors will receive one hard copy of full paper, individual print certificates and digital certificates, Submit Manuscript

CALL FOR PAPERS : DEC-2018

Submission Last Date :  30-Dec-2018
Acceptance Notification :  in 15 days
Publication Date :  in 5 days
Submit Manuscript Online

FOR AUTHORS

FOR REVIEWERS

IJRET® PUBLICATIONS

DOWNLOADS

CONTACT US

NEWS & UPDATES

Call for Paper Vol-7 Iss-02 Feb-2018

IJRET invites papers from various engineering disciplines for Volume-07 Issue-02, Feb-2018.

Submit Manuscript

Published Vol-07 Iss-01 Jan-18

IJRET Volume-07 Issue-01, Jan-2018 is published now.

Browse Papers

ASYMMETRICAL FAULT DETECTION IN DE-ENERGIZED DISTRIBUTION FEEDER

Gajanan Vedpathak, Ajay Kashid, VRSV Bharath Pulavarthi

Abstract: After maintenance or repairing of the de-energized distribution feeder there is need of safely energizing of feeder for the utility’s safety. The safely energizing can be done by determining the fault exists on the distribution system before energizing the system again. The fault detection in de-energized distribution feeder is more difficult than the energized distribution feeder since it requires the system level voltage production and execution to the downstream. Here we implemented an asymmetrical fault detection method to detect the fault before re-energizing the distribution feeder. A controllable signal is feed into de-energized distribution feeder using a thyristor based device to generate the electrical response. The strength of signal can be adjusted from low to high to detect low impedance fault at the beginning, since the maximum faults on distribution system are low impedance faults. A low strength signal may act as an alarm to the personnel or animal in contact with the live part of the system so that they can get away from the system to avoid getting sudden electric shock. Also the major faults on distribution systems are asymmetrical faults so it is necessary to identify and detect the asymmetrical faults before Re-energizing the feeder. The detection and classification of different asymmetrical faults is also explained in this paper. For the determination of the faults we are analyzing the voltage and current signals of the downstream feeder. The fault detection algorithm and control strategies of thyristors are also described for different faults and analyzed by using computer simulation in MATLAB.

Keywords: Fault Detection, Fault Classification, De-Energized Distribution Feeder

DOI: https://doi.org/10.15623/ijret.2015.0404132

Home | Publication Ethics | Privacy Policy | Terms & Conditions | Refund Policy | Feedback | Contact Us
Copyright © 2012-2018 IJRET Journal All rights reserved