IJRET
  • CrossRef
  • Google Scholar
  • ischolar
  • Index Copernicus
  • IJRET
  • Alternate Text
  • IJRET
  • IJRET
  • IJRET
  • Alternate Text
  • IJRET
  • IJRET
  • IJRET
  • IJRET
  • IJRET
  • IJRET
  • IJRET
Authors will receive one hard copy of full paper, individual print certificates and digital certificates, Submit Manuscript

CALL FOR PAPERS : DEC-2018

Submission Last Date :  30-Dec-2018
Acceptance Notification :  in 15 days
Publication Date :  in 5 days
Submit Manuscript Online

FOR AUTHORS

FOR REVIEWERS

IJRET® PUBLICATIONS

DOWNLOADS

CONTACT US

NEWS & UPDATES

Call for Paper Vol-7 Iss-02 Feb-2018

IJRET invites papers from various engineering disciplines for Volume-07 Issue-02, Feb-2018.

Submit Manuscript

Published Vol-07 Iss-01 Jan-18

IJRET Volume-07 Issue-01, Jan-2018 is published now.

Browse Papers

NEW STUDY ON FRICTION IN A MOM TOTAL HIP PROSTHESIS WITH BALLS IN SELF-DIRECTED MOTION

Dumitru Catalin Bursuc, Lucian Capitanu, Virgil Florescu

Abstract: Although Metal-On-Metal (MOM) Total Hip Prostheses (THP) with self directed balls have as their greatest advantage the replacement of the specific regular hip prostheses sliding movement between the femoral head and the acetabulum socket with the rolling movement between the balls, the socket and the femoral head, the lubrication side of the process is still not well known. Tests with balls on a flat rig showed maximum values for the friction coefficient of under 0.05 while studies of lubrication with saline solution have indicated an EHL lubrication schedule, with a minimum value for the thickness of the lubrication film (hmin), measured through the contact resistance methodology, of 0.06 µm. There are obvious trends of seizure in the operation of these prostheses. However, preliminary studies on lubrication in Metal-On-Metal prostheses also showed a clear seizure tendency. For the purposes of the present study we opted for changing the constructive version, adopting a modified motion Omnitrack solution, adapted for use in an artificial hip joint. After testing on an experimental device, the results were spectacular. The minimum friction coefficient value is 0.007, while the maximum value reaches 0.02.

Keywords: Metal on metal total hip prosthesis, balls, self directed movement, lubrication, friction coefficient

DOI: https://doi.org/10.15623/ijret.2014.0304015

Home | Publication Ethics | Privacy Policy | Terms & Conditions | Refund Policy | Feedback | Contact Us
Copyright © 2012-2018 IJRET Journal All rights reserved