IJRET
  • CrossRef
  • Google Scholar
  • ischolar
  • Index Copernicus
  • IJRET
  • Alternate Text
  • IJRET
  • IJRET
  • IJRET
  • Alternate Text
  • IJRET
  • IJRET
  • IJRET
  • IJRET
  • IJRET
  • IJRET
  • IJRET
Authors will receive one hard copy of full paper, individual print certificates and digital certificates, Submit Manuscript

CALL FOR PAPERS : DEC-2018

Submission Last Date :  30-Dec-2018
Acceptance Notification :  in 15 days
Publication Date :  in 5 days
Submit Manuscript Online

FOR AUTHORS

FOR REVIEWERS

IJRET® PUBLICATIONS

DOWNLOADS

CONTACT US

NEWS & UPDATES

Call for Paper Vol-7 Iss-02 Feb-2018

IJRET invites papers from various engineering disciplines for Volume-07 Issue-02, Feb-2018.

Submit Manuscript

Published Vol-07 Iss-01 Jan-18

IJRET Volume-07 Issue-01, Jan-2018 is published now.

Browse Papers

PERFORMANCE ANALYSIS OF THREE PHASE SHUNT HYBRID ACTIVE POWER FILTER

Sangamesh Bukka, Mohammad Yunus M Hakim, Sanjeev T.M, S. G. Ankaliki

Abstract: Active filtering of electric power has now become a mature technology for harmonic and reactive power Compensation in AC networks. The past several years have seen a rapid increase of power electronics-based loads connected to low and medium voltage power distribution systems. These loads draw non-sinusoidal current from the mains, degrading the power quality by causing harmonic distortion. This paper proposes a three phase Shunt Hybrid Active Filter (SHAF) topology for harmonic reduction and power factor improvement in low voltage power distribution systems. The compensation current reference for the proposed SHAF topology is obtained by using synchronous reference frame theorem. This theorem simplifies the equations for the current reference estimation in d-q co-ordinates thus leading to a more efficient and fast computation. To generate the compensation current that follows the current reference, the hysteresis current control method is adopted for 2-level VSI in low voltage system, the system is verified by developing simulation model using MATLAB/Simulink simulation package and the results are presented. The performance of shunt active filter and the proposed shunt hybrid active filter topology in reducing total harmonic distortion (THD) is compared for low voltage distribution system.

Keywords: SAPF, SHPF, PI control, THD, Hysteresis current pulse width modulation, D-Q reference frame theory.

DOI: https://doi.org/10.15623/ijret.2014.0303048